Home> Products> Compressed Air Filter> Aluminum Air Filter> Compressed Air Treatment Equipment Market
Compressed Air Treatment Equipment Market
Compressed Air Treatment Equipment Market
Compressed Air Treatment Equipment Market

Compressed Air Treatment Equipment Market

$125.281-19 Piece/Pieces

$119≥20Piece/Pieces

Payment Type:T/T,L/C
Incoterm:CIF,EXW,CFR,FOB
Transportation:Land,Ocean,Air,Express
Port:Shenzhen,Guangzhou,Shanghai
Product Attributes

Model No.HFD070

OriginChina

HS Code8421399090

ClapboardWithout Clapboard

Filter Number1

Medium MaterialFiberglass

TypeCartridge Filter

MaterialAluminum Alloy

Housing Serve Lige15 Years

Filtration PerformanceFrom 5 μm To 0.01μm

Operate Temperature1.5~80ºc

Resistance CorrosionInside And Outside

Transport PackageBrown Inner Box & Cardboard

Filtration GradeMedium Filter

ColorLight Blue

ConnectionRc1"

Flow Rate7.2m³/Min

Maxi. Operate Pressure1.6mpa

EfficiencyF9

Element Serve Life4000~6000 Hours

ConfigurationStainless Steel Manual Ball Valve

Filter ElementTop & Bottom Cap With Stainless Steel

Connection & Wall Connection KitYes

SpecificationDimension: 120 X 113 X 459 Mm

Packaging & Delivery
Selling Units : Piece/Pieces
Package Type : Carton Boc
Picture Example :
Product Description

Compressed air in industrial applications contains in 1Nmᶟ more than 100 million of polluting articles. Most of these particles are so small in dimension, less than 5 micron, that they cannot be intercepted by the standard intake filters installed in the compressors. Such particles, mixed with water and oil vapour generated during compression, cause the early wear and tear of the appliances and consequently they are the cause of expensive interruptions of the production and remarkable increase maintain.


 

Selection right Air Filters will allow the best choice of the suitable equipment according to the quantity of air to be treated and the necessary filtration degree in order to increase and improve the performances of the whole system. 



How to choose right filter for Your Air Compressor System?

When you’re working with air compressors, air purification and filtration is an critical part of maintenance. Compressed air filters play an important role in your industrial air compressor system. Choosing the right filter not only increases the efficiency of your unit, but it can also reduce energy costs and protect your employees from harmful chemicals and particulates.

 

However, does all air filter work for your compressed air system? Well it is depending on your working conditions, the project you’re completing and how often you use your equipment, you’ll need to make an precise choice. This guide will detail how air compressor filters work, why they’re important, what type of Air Compressor Filter to buy and when you should replace it.

Feature & Advance

①1.6Mpa working pressure, connection and wall kit available, save install time and money.

②15 years warranty for filter housing, thanks for die-casting integrated technology.

③Filtration accuracy up tp 0.01μm, oil mist residual up to 0.001mg/m³, class 1 in according with ISO8573.1-2010 standard.

④Low pressure drop, saving energy and positive efficiency.




HFD series with 7 Grades Filter Element:  PF/AO/AA/AX/ACS/AR/AAR


PF AO AA AX ACS AR AAR
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21℃),1ppm(w). High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21),0.01ppm(w) Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21),0.001ppm(w) Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21)0.003ppmw Dust particles whose diameter more than 1μm can be removed Dust particles whose diameter more than 0.01μm can be removed




Product Specification

Model) Pipe size Flow rates Dimension (mm)
L/S m³/min scfm W (Width) D  (Depth) H (Height) A B
HFD010 RC1/2" 16.7  1.0  35.3  90 82 255 37 179
HFD020 RC3/4" 25.0  1.5  53.0  90 82 255 37 179
HFD030 RC3/4" 30.0  1.8  63.6  90 82 286 37 212
HFD040 RC1" 33.3  2.0  70.6  90 82 286 37 212
HFD050 RC3/4" 46.7  2.8  98.9  120 113 359 53 269
HFD060 RC1" 60.0  3.6  127.1  120 113 359 53 269
HFD070 RC1" 80.0  4.8  169.5  120 113 459 53 369
HFD080 RC1-1/2" 120.0  7.2  254.2  120 113 459 53 369
Technical requirements Maximum operating pressure: 16 barg                                                                                                                      Maximum operating temperature: 80°C                  Minimum operating temperature:1.5°C

Pressure Barg 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Psig 15 29 44 59 73 87 100 116 131 145 160 174 189 203 219 232
Correction factor 0.38 0.53 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51

                                                                                          coalescer fitler cartridge


                                                   


How to install Compressed Air Filter?

 

1. Clean the compressed air pipes and valves connected to the air inlet and outlet of the filter before installation.

 

2. Adopt the combination of main pipe filtration and terminal filtration to ensure the gas quality at the point of use.

 

3. When installing, the air inlet and outlet of the filter should be kept level, and the sewage outlet should be at the bottom. A certain space must be reserved in the vertical direction to facilitate the maintenance of the filter and the replacement of the filter element.

 

4. The filter of the screw air compressor should be installed in a ventilated and cool place, as close as possible to the air point, to reduce the influence of the pipeline on the quality of the filtered compressed air.

 

5. Install and use within the specified working pressure and working temperature range, and install all levels of filters in the correct order according to the air inlet and outlet instructions or the direction indicated by the arrow, from coarse to fine installation. Avoid bypass as much as possible during installation. Because the oil in the air is bypassed to the downstream of the filter and then sticks to the inner wall of the pipeline, it is difficult to find effective means to remove it.

 

6. The filter element should be replaced regularly. Carefully record the replacement time. It is recommended that the working time zone should not exceed 6000 hours.

 

7. The discharge time of the auto drain is suitable for draining the liquid water, and the discharge interval is subject to the water content in the pipeline;

 

8. Different grades of compressed air filters can be equipped with zero pressure loss floating ball drain valves or manual valves according to customer requirements.


Home> Products> Compressed Air Filter> Aluminum Air Filter> Compressed Air Treatment Equipment Market
Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send