Home> Products> Compressed Air Filter> Aluminum Air Filter> Air Compressor Intake Filter Element
Air Compressor Intake Filter Element
Air Compressor Intake Filter Element
Air Compressor Intake Filter Element

Air Compressor Intake Filter Element

$345.781-19 Piece/Pieces

$328.5≥20Piece/Pieces

Payment Type:L/C,T/T
Incoterm:FOB,CFR,CIF,EXW
Transportation:Ocean,Land,Air,Express
Port:Shenzhen,Guangzhou,Shanghai
Product Attributes

Model No.DT019

BrandYUKA

Working Pressure1.0mpa

Element GradePf/Ao/Aa/Ax/Acs/Ar/Aar

Connection SizeRc1-1/2"

Anti-corrosion TreatmentInside & Outside

Element DesignNo-Touch

Air Filter Housing15 Years Lifespan

Woking Temperature Range1.5℃-80℃

Element Main MaterialBorosilicate Microfiber Glass

Filtration Accuracy0.01 Micron, 0.001mg/M³

Flow Rate6.0m³/Min

Packaging & Delivery
Selling Units : Piece/Pieces
Package Type : Carton
Picture Example :
Without Tid-rod Air filter
Product Description

Product Feature & Advantage

①Filter housing with 100% leakage-tested in three times, with 15 years spanlife. Low overall costs for owner.

②No-touch element design, easy to maintenance and repaired.

③Design as ISO8573.1-2010 standard in class 1 Level filtration performance. Protect your precise equipment and optimization your production.

④Low pressure drop, saving energy and cost.

⑤Fitted for all applications and all type of air compressor.


Element Grade Filter Type Filtration Accuracy Oil Concentration Remark
PF Prefilter ≤ 5 μm Can be negligible Before air dryer
AO Medium filter ≤ 1 μm ≤ 1ppm After air dryer
AA High Precision filter ≤ 0.01 μm ≤0.01ppm Behind grade AO
ACS Activated Carbon Filter / ≤0.003ppm Behind grade AA
AX Ultra-high precision filter ≤ 0.01 μm ≤0.001ppm Behind grade ACS
AR Particulate air filter 1μm - After Desiccant Air Dryer
AAR Particulate Air Filter
0.01μm - After grade AR

What to do if Pressure drop becomes larger?

1. If the Air Filter Element is clogged or the adsorption capacity is too large, replace the Filter Element.
2. The intake impurity load is large and pre-treatment is performed.
3. If the filter cartridge has accumulated water, find out the cause and drain the remaining accumulated water.
4. The automatic drainer fails, adjust and repair or replace the auto drainer.
5. The filter installation is not level, reinstall it.


Air filter near me


Technical Specification

Model Pipe size Flow rates Dimension (mm)
L/S m³/min scfm W (Width) D (Depth) H (Height) A B C (clearance for housing)
DT009 RC1/4" 5.0  0.3  10.6  80.6 69.0 224.1 24.6 173.9 50.5
DT010 RC3/8" 10.0  0.6  21.2  80.6 69.0 224.1 24.6 173.9 50.5
DT011 RC1/2" 20.0  1.2  42.4  108.2 93.3 275.3 30.1 220.6 53.3
DT012 RC3/4" 25.1  1.5  53.0  108.2 93.3 275.3 30.1 220.6 53.3
DT013 RC1/2" 30.1  1.8  63.5  108.2 93.3 315.3 30.1 260.6 53.3
DT014 RC3/4" 33.4  2.0  70.6  108.2 93.3 315.3 30.1 260.6 53.3
DT015 RC3/4" 46.8  2.8  98.8  133.0 113.9 399.6 40.7 291.0 59.6
DT016 RC1" 60.1  3.6  127.1  133.0 113.9 399.6 40.7 291.0 59.6
DT017 RC1" 80.2  4.8  169.4  133.0 113.9 468.4 40.7 359.8 59.6
DT018 RC1-1/2" 100.2  6.0  211.8  133.0 113.9 468.4 40.7 359.8 59.6
DT019 RC1-1/2" 125.3  7.5  264.8  133.0 113.9 533.7 40.7 425.3 59.6
DT020 RC2" 200.0  12.0  424.0  170.0 158.3 783.1 52.9 623.0 59.6
DT021 RC2" 266.7  16.0  565.3  170.0 158.3 1065.4 52.9 945.3 59.6
DT022 RC2-1/2" 316.7  19.0  671.3  170.0 158.3 1065.4 52.9 945.3 59.6
Technical requirements Maximum operating pressure: 10 barg    Maximum operating temperature: 80°C      Minimum operating temperature:1.5°C

Pressure Barg 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Psig 15 29 44 59 73 87 100 116 131 145 160 174 189 203 219 232
Correction factor 0.38 0.53 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51



Replacement and Spare Parts

Coalescing air filters


                    

Installation Tips of Compressed Air Filter


1. Clean the compressed air pipes and valves connected to the air inlet and outlet of the filter before installation.


2. Adopt the combination of main pipe filtration and terminal filtration to ensure the gas quality at the point of use.


3. When installing, the air inlet and outlet of the filter should be kept level, and the sewage outlet should be at the bottom. A certain space must be reserved in the vertical direction to facilitate the maintenance of the filter and the replacement of the filter element.


4. The filter of the screw air compressor should be installed in a ventilated and cool place, as close as possible to the air point, to reduce the influence of the pipeline on the quality of the filtered compressed air.


5. Install and use within the specified working pressure and working temperature range, and install all levels of filters in the correct order according to the air inlet and outlet instructions or the direction indicated by the arrow, from coarse to fine installation. Avoid bypass as much as possible during installation. Because the oil in the air is bypassed to the downstream of the filter and then sticks to the inner wall of the pipeline, it is difficult to find effective means to remove it.

 

6. The filter element should be replaced regularly. Carefully record the replacement time. It is recommended that the working time zone should not exceed 6000 hours.


7. The discharge time of the auto drain is suitable for draining the liquid water, and the discharge interval is subject to the water content in the pipeline;


8. Different grades of compressed Air Filters can be equipped with zero pressure loss floating ball drain valves or manual valves according to customer requirements.


                